Focus on high-end showcase R&D and manufacture.
+86 13728040213 [email protected]

Jewelry Showcase Site Survey: What Your Manufacturer Needs

November 24, 2026

Jewelry Showcase Site Survey: What Your Manufacturer Needs

A jewelry showcase that fits perfectly on the factory floor is a piece of furniture that arrives by sea freight and does not fit the store. The gap between those two realities is almost always the site survey. When a custom showcase order goes wrong, the cause is rarely the design and rarely the workmanship; it is a dimension that was estimated instead of measured, a column nobody photographed, or a door swing nobody verified. A proper jewelry showcase site survey takes 60 to 90 minutes per retail floor and costs nothing next to rebuilt cabinets, remade glass and a delayed opening. This guide covers exactly what to capture, with the numbers worth writing down, so the information you send your manufacturer is complete on the first pass.

Why a Site Survey Comes Before the Drawing

Most showcase factories work from CAD drawings, and those drawings are only as good as the dimensions behind them. A 10 mm error in a wall-to-wall measurement is invisible on paper but becomes a 10 mm gap in a run of five adjoining units, or a set of doors that will not open past a neighboring fixture. Surveys also reveal what drawings never show: uneven floors, bulkheads, sprinkler heads, low-hanging signage, radiator covers and electrical outlets hidden behind the display line.

The practical rule is simple. If a showcase is built-in, wall-to-wall, taller than 2,400 mm, or installed in a store older than ten years, a site survey is mandatory, not optional. Even for freestanding units, the survey tells the factory how many pieces fit in a 40HQ container, which affects freight cost and breakage risk.

Measurements: The Numbers That Actually Matter

Measure in millimetres and always note the unit. Feet-and-inches conversions are a frequent source of error when a Chinese factory and a US or European store are exchanging files. Record every measurement three times if the wall is irregular, and always use the smallest clear opening, not the average.

  • Room dimensions: length and width at floor level, plus the same measurements at 900 mm (counter height) and at 1,500 mm (eye level), since walls often lean.
  • Ceiling height: from finished floor to lowest obstruction, not to the slab. Note the height and location of bulkheads, beams and sprinkler heads.
  • Clear wall runs: the actual usable length between columns, door frames, radiators and outlets, with each obstruction listed by position and size.
  • Aisle widths: minimum 900 mm for one customer, 1,200 mm where two people must pass, and check local accessibility rules for wheelchair turning circles (commonly 1,500 mm).
  • Counters and cash wraps: position, height (typically 900–1,100 mm) and depth, so showcases are sized to sit alongside rather than collide.
  • Floor flatness: a 2 m straightedge with a feeler gauge tells you the fall. More than 3 mm variation across 2 m means adjustable feet or a plinth will be required.
  • Doors and delivery route: the narrowest external door, corridor widths, lift dimensions and stair turns, plus stair riser heights. If the showcase cannot pass, it cannot be delivered.
  • Electrical: outlet positions and heights, circuit capacity, and whether lighting will need 12 V or 24 V drivers, all confirmed with the store electrician or landlord.

Photograph the tape measure in every wide shot. A measurement with no reference photo is a number waiting to be questioned.

Photos: The Shots That Prevent Redesigns

Aim for 40 to 60 photos per store, taken with the same phone so colors remain consistent. Stand at each corner of the room and shoot toward the opposite corner, then work around the walls. Include close-ups of every obstruction: columns, pilasters, conduits, uneven patches, fire equipment and access panels. Photograph the floor finish closely, the ceiling grid, and the view from the entrance so the manufacturer understands sightlines and traffic flow.

One useful extra: place an A4 sheet of paper or a standard 300 mm ruler on the floor at a known distance and photograph it. It gives the factory a scale reference for judging surfaces and heights when the line drawings leave room for doubt.

Drawings and Supporting Documents

Photos and numbers are stronger with a rough floor plan, even a hand sketch scanned at high resolution. Mark the store entrance, the customer path, the security desk, and the intended location of every showcase. If an architect, shopfitter or landlord has drawing files, send those too, along with the store fit-out schedule and the planned opening date. Tell the manufacturer about brand standards: glass type and thickness (10 mm or 12 mm is common for jewelry counters), finish colors, hardware style and any logo application. If your lighting is specified by a consultant, include the color temperature (3000 K is common for gold, 4000 K for diamonds) and lumens per linear meter.

Common Survey Mistakes That Cost Real Money

Measuring to baseboards rather than to the wall, forgetting to note which side a door swings, and photographing a showroom during trading hours so racks and people block the walls are the three most frequent failures. Another one: assuming the floor is level. We have seen a 12 mm fall across three meters turn a seamless glass display run into a staggered installation.

Send everything in one organized package: a single PDF with the sketch, the dimension table and numbered photos, named by room or wall. Factories can quote from that package in two to four working days instead of exchanging a dozen messages over two weeks. Libafang works from surveys like this every week and can flag conflicts before the drawing stage, which is when changes are still free.

Ready to Turn Your Survey Into a Design

Once measurement, photos and layout notes are in hand, the next step is a dimensioned design and a firm quotation. If you are planning a jewelry store, watch boutique or museum installation, send your requirements, store size and closing date, and our team will return a space plan, material specification and a cost estimate. Request a free design and quote from Libafang and put your site information to work.

Do you need a product catalog and price list?